1.Basic introduction
SR series safety relays is a new type of safety relays,beautiful appearance,structure compact,and reach to the best safety by the smallest cost.SR series safety relays is a kind of products designed according to the European design standards,certified by European safety standard CE and has achieved national CCC safety certification,correspond to 2006/42/EC,2004/108/EC,EN ISO 13849-1,EN 60947-4-1,EN 60947-5-1 and so on standards. Safety relays are widely used in safety light curtain,safety door,a sudden stop switch and so on safety and sudden loop, can set double channel operation to make sure security, to prevent accident and stop.
2. SR seriess specification
SR has several specification.They are SR4P2A1B22,SR4P2A1B24,SR4P2A1B24P,SR4P2A1B24N,SR4P3A1B24,SR4P2A1B24S,
SR4P2A1Y,SR2P4A24
The SR4P2A1B22 and SR4P2A1B24 are appropriate for E-stop Switch,Safety Gate.
The SR4P2A1B24P is appropriate for safety light curtain(PNP).
The SR4P2A1B24N is appropriate for safety light curtain(NPN).
The SR4P3A1B24 is appropriate for E-stop Switch,Safety Gate.
The SR4P2A1B24S is appropriate for two-hands button.
The SR4P2A1Y is appropriate for E-stop Switch,Safety Gate.
The SR2P4A24 is appropriate for external of safety module.
3.Technology specification
Supply voltage |
85-264V AC/DC |
Power consumption |
3 W |
Frequency range |
50-60 HZ |
Switched capacity(EN60947-5-1) |
AC-15,5A/250V DC-13,6A/24V |
Output contact |
2N/O,1N/C |
Contact fuse protection |
4A T/6A F |
Max overall cable resistance input circuit |
DC 100ohm |
Dual-channel with detection of shorts across contacts |
AC 100ohm |
Switch-on delay(automatic reset) |
35ms |
Switch-on delay(manual reset) |
30ms |
Delay-on |
10ms |
Max supply interruption before power failure |
1s |
Shake suitability |
EN60068-2-6 |
Frequency |
10-55Hz |
Amplitude |
0.33mm |
Protection housing |
IP50 |
Max cable cross section |
0.2-2.5mm2 |
Dimention |
96x22.5x116 |
Weight |
340g |
Mounting |
35mm DIN rail |
4. Detail introduction
SR series safety relay controls one set light curtain, is mounted inside the electrical cabinet.
SR series safety relay is directly inserted into 35mm rails of the inside electrical cabinet of press or equipment.
If periphery has strong electromagnetism noise source(for example transducer,high frequency machine and so on),the controller should be far away from them to avoid the interference.
(1)Output various form,widely application.
(2)The input contactss short citcuit fault can be detected,safety performance is good.
(3)You can choose manual reset or automatic reset,operation convenience.
(4)It has self monitoring redundancy circuit ,safety performance is good.
(5)It has status indicators,facilitate fault ispection.
(6)It has removable terminals,facilitate installation and connection.