1.Basic introduction
SNQ series, sensor section size is 53 脳35,structure compact,beautiful outlook,mainly be used in small stamping equipment, shearing equipment, machinery processing equipment, the injection molding machinery and paper cutting machinery, woodworking machinery, three-dimensional garage, and other dangerous areas protection.
2.SNQ seriess specification
Protection range,2 sides protection<=6000mm,3 sides<=4000mm;
Specification
SNQxx20 (xx=06, 08, 10, 12......72)
SNQxx30 (xx=06, 08, 10, 12......72)
SNQxx40 (xx=04, 06, 08, 10......36)
SNQxx80 (xx=02, 04, 06, 08......20)
Light axis pitch 20mm, 30mm, 40mm, 80mm
Protection height=(xx-1)脳light axis pitch
SNQxx20 100,140,180,220......1420mm
SNQxx30 150,210,270,330......2130mm
SNQxx40 120,200,280,360......2840mm
SNQxx80 80,240,400,560......1520mm
3.Working principle
The protector consists of light curtain,signal cables,controller and control cables.The light curtain can form infrard light curtain,detect the signal of passing or intercepting,and send the signal to control box that also supplies power to the light curtain.The control box processes the signal and outputs the closed or opened signal used safety relay,and then connects the control trip circuit of the press by control cable or other protective equipment to protect the workers.
4.Detailed introduction
(1)SNQ series is based on STD series,using 1 or 2 mirrors reflecting the beams,changing the transmission.
(2)Light curtain form:Plane mirror reflect
(3)Standard configuration:
2 sides protection : Emitter/1,Mirror/1,Receiver/1,N type controller/1,Signal cable 3m/1 root,8m/1 root,Installation fittings/1 set;
3 sides protection:Emitter/1,Mirror/2,Receiver/1,N type controller/1,Signal cable 3m/1 root,8m/1 root,Installation fittings/1 set;
(4)It is allowed to choose W type controller
(5)Controller:
N type, inside installation,control 1 set light curtain,the power source is AC220V/110V(terminals) or DC24V; W type, outside installation,control 1 set light curtain,the power source is AC220V/110V(switch conversion) or DC24V; controller cable is equipped with standard length: N type 1.0m ,W type 2.5m.
(5)It can provide NPN output, at this time, we should guarantee the follow-up control circuit correspond to safety requirements and provide DC24V power source.
(6)Prompts specially:
If the power source need to be DC24V,the special explanation should be made on order.
If the length of signal and controller cables need to lengthen,the special explanation should be made on order;
5. Application examples