Product name:Safety Light Curtain STD Series
Time:2012-07-17
Company:
Feedback
Details

1.Basic introduction

STD Series infrared light curtain series, sensor section size is 74 脳50,structure compact,beautiful outlook,mainly be used in small stamping equipment, shearing equipment, machinery processing equipment, the injection molding machinery and paper cutting machinery, woodworking machinery, three-dimensional garage, and other dangerous areas protection.

2.STD seriess specification
Protection range: 0-15000mm;
Specification
STDxx10 (xx=24, 32, 40, 48, 56......136)

STDxx20 (xx=08, 12, 16, 20, 24......72)

STDxx40 (xx=04, 06, 08, 10, 12......72)

STDxx80 (xx=02, 04, 06, 08,12......20)

Light axis pitch 10mm,20mm, 40mm,80mm

Protection height=(xx-1)脳light axis pitch

STDxx10  230,310,390,470......1350mm

STDxx20 140,220,300,380......1420mm
STDxx40 120,200,280,360......2840mm
STDxx80   80,240,400,560......1520 mm
3.Working principle

The protector consists of light curtain,signal cables,controller and control cables.The light curtain can form infrard light curtain,detect the signal of passing or intercepting,and send the signal to control box that also supplies power to the light curtain.The control box processes the signal and outputs the closed or opened signal used safety relay,and then connects the control trip circuit of the press by control cable or other protective equipment to protect the workers.

4.Detailed introduction

7-1STD

 

(1)Characteristic:The installation and adjustment are convenient,the wiring is simple, structure compact, the   contour is artistic.
(2)Light curtain form:Direct transmission type.
(3)Standard Configuration:
Emitter/1,Receiver/1,W type controller/1,Signal cable 3m/1 root, 10m/1 root ,Installation fittings/1 set;
It is allowed to choose W type controller,at this time ,signal cables are 3m/1 root,10m/1 root.

(4)Controller:
N type, inside installation,control 1 set light curtain,the power

source is AC220V/110V(terminals) or DC24V; W type, outside installation,control 1 set light curtain,the power source is AC220V/110V(switch conversion) or DC24V; controller cable is equipped with standard length: N type 1.0m ,W type 2.5m
(5)It can provide NPN ,PNP output, at this time, we should guarantee the follow-up control circuit correspond to safety requirements and provide DC24V power source.
(6)Prompts specially:
If the power source need to be DC24V,the special explanation should be made on order.
If the length of signal and controller cables need to lengthen,the special explanation should be made on order;